E2 AireCare TM Electronic Air Filter
Installation Instructions
(5 Ton A/C)
Before starting this installation, make sure that
all electrical power to the furnace has been
disconnected.
The 5 Ton E2 AireCare TM ElectronicAir Filter kit
consists of a through the wall grille and frame kit
and the electronic air filter with power cable.
Install Frame
1. Cut a rough-in opening (20" wide by 30"
high) in the door or wall enclosing the E2
furnace.
2. Mount the frame kit into the opening using
screw or wall board anchors.
Connect the AireCare TM
Electronic Air Filter
1. Connectthe electronicairfilterpowerwires
(24 VAC) to the red and gray (or black) low
voltage terminals (R and C). Run this wire
from the E2 furnace to the electronic air
filter and frame. Connect the power wire
marked with a white stripe or dash to C, the
other to R.
2. Place the electronic air filter into the frame
and connect the filter power cable by plug-
ging it into the connector located at the top
of the electronic air filter.
3. Turn on power to the furnace. The
AireCare TM Electronic Air Filter is active if
the light on top of the electronic air filter is
lit.
4. Coverelectronicairfilterwith supplied grille.
E2 Grille
Electronic
Air Filter
Filter
Frame
E2 Frame
Figure 1. E2 Bracket installation